Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.22.03
Symptom: For the OS of the G7 server installed with the FIST SMS agent, if you use the Redfish API to obtain the drive usage, the system fails to obtain the drive list.
Condition: This symptom might occur if you use the Redfish API to obtain the drive usage from the OS of the G7 server installed with the FIST SMS agent.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.22
Symptom: When the R4930 G7 server is installed with a specific DPU, HDM fails to display processor information.
Condition: This symptom might occur if the R4930 G7 server is installed with a specific DPU.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.21.01
Symptom: If the G7 server is installed with the RAID-Linkdata-3260-LP-10i-4GB or RAID-Linkdata-3260-LP-18i-8GB storage controller, the reading on the corresponding temperature sensor is incorrect.
Condition: This symptom might occur if the G7 server is installed with the RAID-Linkdata-3260-LP-10i-4GB or RAID-Linkdata-3260-LP-18i-8GB storage controller.
Symptom: During the restart of the G7 server after an AC power-off, the server fails to automatically start up.
Condition: This symptom might occur if the G7 server restarts after an AC power-off.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.21
Symptom: The R4900 G7 server reports a Config Error alarm when configured with a MEZZ Riser adapter card.
Condition: This symptom might occur when the R4900 G7 is configured with a MEZZ Riser adapter card.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.20.01
Symptom: The Firmware & Software page on HDM for the R5500 G7 gets stuck.
Condition: This symptom might occur if you access the Firmware & Software page on HDM for the R5500 G7 installed with specific modules.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.19.02
None.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.19
None.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.18
Symptom: On the R4950 G7 equipped with an LSI 95XX series RAID controller, if you switch the MCTP over PCIe channel and then reboot the host, HDM takes an exceptionally long time to recognize the storage controller and drive information.
Condition: This symptom might occur on the R4950 G7 equipped with an LSI 95XX series RAID controller if you switch the MCTP over PCIe channel and then reboot the host.
Symptom: On a G7 server equipped with a NIC-ETH-SF400T-C201-3S-4P network adapter, if you issue a self-test IPMI command to HDM, the system returns a self-test failure result.
Condition: This symptom might occur on a G7 server equipped with a NIC-ETH-SF400T-C201-3S-4P network adapter.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.17
None.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.16.02
Symptom: For G7 servers managed by OpenIPMI, when you send specific IPMI commands, the response might fail.
Condition: This symptom might occur if G7 servers managed by OpenIPMI
Symptom: For the server configured with the P460 storage controller, HDM reports the Battery failed alarm in an out-of-band manner and clears the alarm one minute later.
Condition: This symptom might occur if the server is configured with the P460 storage controller.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.16.01
Symptom: When the server is configured with both a PMC storage controller and an IB-MCX653105A-HDAT-200Gb-1P network adapter, with the network adapter firmware version at 20.37.10.14, HDM is unable to retrieve the information of the drives connected to the PMC storage controller.
Condition: This symptom might occur if the server is configured with both a PMC storage controller and an IB-MCX653105A-HDAT-200Gb-1P network adapter, with the network adapter firmware version at 20.37.10.14.
Symptom: On G7 servers, HDM generates false positive logs for network port up/down events.
Condition: This symptom might occur if a G7 server is equipped with a specific network adapter.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.15
None.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.14.02
Symptom: HDM might automatically restart if stress tests are performed through IPMI commands in the server system in an in-band manner.
Condition: This symptom might occur if stress tests are performed through IPMI commands in the server system in an in-band manner.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.13.01
None.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.12.05
None.
New Functions
Upgrade recommendations
Optional for update
Problems Solved
Resolved problems in HDM3-2.11.02
None.
New Functions
Version:2.08.10(2025/10/23)
Upgrade recommendations
recommended
Problems Solved
Resolved problems in HDM3-2.08.10
Symptom: HDM restarts automatically after the server operates for a period with specific configurations.
Condition: This symptom might occur after the server operates for a period with specific configurations.
New Functions
Upgrade recommendations
optional for update
Problems Solved
Resolved problems in HDM3-2.06.06
Symptom: After you restart the server installed with both the domestic BMC card and LSI storage controller, HDM fails to identify the LSI storage controller.
Condition: This symptom might occur if you restart the server installed with both the domestic BMC card and LSI storage controller.
New Functions